EATON 34105 2 Kademeli Sıfırlı 1x20A Pako Şalter
Marka: Eaton
Orijinal fiyat: 836,66₺.292,83₺Şu andaki fiyat: 292,83₺.
10.000₺ ve üzeri alışverişlerinize özel teklif.
EATON 34105 1-8240/E T0 1x20A Pako Şalter (2 Kademeli, sıfırlı)
Datasheet – T0-1-8240/E | |||
Part no. | T0-1-8240/E | ||
Article no. | 034105 | ||
Catalog No. | 034105 | ||
1150PIC-1222 | |||
Similar to illustration | |||
Delivery program | |||
Product range | Control switches | ||
Part group reference | T0 | ||
Basic function | Step switches | ||
with black thumb grip and front plate | |||
Contacts | 2 | ||
Number of steps | 2 steps, 45° | ||
Degree of Protection | Front IP65 | ||
Design | flush mounting | ||
000Z079 | |||
Contact sequence | 115S027-2 | ||
Switching angle | ° | 45 | |
Switching performance | maintained With 0 (Off) position | ||
Design number | 8240 | ||
Front plate no. | 115K016 | ||
front plate | 0-2 | ||
Motor rating AC-23A, 50 – 60 Hz | |||
400 V | P | kW | 5.5 |
Rated uninterrupted current | Iu | A | 20 |
Note on rated uninterrupted current !u | Rated uninterrupted current Iu is specified for max. cross-section. | ||
Number of contact units | contact unit(s) | 1 | |
Technical data | |||
General | |||
Standards | IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL Switch-disconnector according to IEC/EN 60947-3 | ||
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 | ||
Ambient temperature | |||
Open | °C | -25 – +50 | |
Enclosed | °C | -25 – +40 | |
Overvoltage category/pollution degree | III/3 | ||
Rated impulse withstand voltage | Uimp | V AC | 6000 |
Mechanical shock resistance | g | 15 | |
Mounting position | As required | ||
Contacts | |||
Electrical characteristics | |||
Rated operational voltage | Ue | V AC | 690 |
Rated uninterrupted current | Iu | A | 20 |
Note on rated uninterrupted current !u | Rated uninterrupted current Iu is specified for max. cross-section. | ||
Load rating with intermittent operation, class 12 | |||
AB 25 % DF | x Ie | 2 | |
AB 40 % DF | x Ie | 1.6 | |
AB 60 % DF | x Ie | 1.3 | |
Short-circuit rating | |||
Fuse | A gG/gL | 20 | |
Rated short-time withstand current (1 s current) | Icw | Arms | 320 |
Note on rated short-time withstand current lcw | Current for a time of 1 second | ||
Rated conditional short-circuit current | Iq | kA | 6 |
Switching capacity | |||
cos ϕ rated making capacity as per IEC 60947-3 | A | 130 | |
Rated breaking capacity cos ϕ to IEC 60947-3 | A | ||
230 V | A | 100 | |
400/415 V | A | 110 | |
500 V | A | 80 | |
690 V | A | 60 | |
Safe isolation to EN 61140 | |||
between the contacts | V AC | 440 | |
Current heat loss per contact at Ie | W | 0.6 | |
Current heat loss per auxiliary circuit at Ie (AC-15/230 V) | CO | 0.6 | |
Lifespan, mechanical | Operations | x 106 | > 0.4 |
Maximum operating frequency | Operations/h | 1200 | |
AC | |||
AC-3 | |||
Rating, motor load switch | P | kW | |
220 V 230 V | P | kW | 3 |
230 V Star-delta | P | kW | 5.5 |
400 V 415 V | P | kW | 5.5 |
400 V Star-delta | P | kW | 7.5 |
500 V | P | kW | 5.5 |
500 V Star-delta | P | kW | 7.5 |
690 V | P | kW | 4 |
690 V Star-delta | P | kW | 5.5 |
Rated operational current motor load switch | |||
230 V | Ie | A | 11.5 |
230 V star-delta | Ie | A | 20 |
400V 415 V | Ie | A | 11.5 |
400 V star-delta | Ie | A | 20 |
500 V | Ie | A | 9 |
500 V star-delta | Ie | A | 15.6 |
690 V | Ie | A | 4.9 |
690 V star-delta | Ie | A | 8.5 |
AC-23A | |||
Motor rating AC-23A, 50 – 60 Hz | P | kW | |
230 V | P | kW | 3 |
400 V 415 V | P | kW | 5.5 |
500 V | P | kW | 7.5 |
690 V | P | kW | 5.5 |
Rated operational current motor load switch | |||
230 V | Ie | A | 13.3 |
400 V 415 V | Ie | A | 13.3 |
500 V | Ie | A | 13.3 |
690 V | Ie | A | 7.6 |
DC | |||
DC-1, Load-break switches L/R = 1 ms | |||
Rated operational current | Ie | A | 10 |
Voltage per contact pair in series | V | 60 | |
DC-21A | Ie | A | |
Rated operational current | Ie | A | 1 |
Contacts | Quantity | 1 | |
DC-23A, motor load switch L/R = 15 ms | |||
24 V | |||
Rated operational current | Ie | A | 10 |
Contacts | Quantity | 1 | |
48 V | |||
Rated operational current | Ie | A | 10 |
Contacts | Quantity | 2 | |
60 V | |||
Rated operational current | Ie | A | 10 |
Contacts | Quantity | 3 | |
120 V | |||
Rated operational current | Ie | A | 5 |
Contacts | Quantity | 3 | |
240 V | |||
Rated operational current | Ie | A | 5 |
Contacts | Quantity | 5 | |
DC-13, Control switches L/R = 50 ms | |||
Rated operational current | Ie | A | 10 |
Voltage per contact pair in series | V | 32 | |
Control circuit reliability at 24 V DC, 10 mA | Fault probability | HF | -5,< 1 failure in 100,000 switching operations |
Terminal capacities | |||
Solid or stranded | mm2 | 1 x (1 – 2,5) 2 x (1 – 2,5) | |
Flexible with ferrules to DIN 46228 | mm2 | 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) | |
Terminal screw | M3.5 | ||
Tightening torque for terminal screw | Nm | 1 | |
Technical safety parameters: | |||
Notes | B10d values as per EN ISO 13849-1, table C1 | ||
Rating data for approved types | |||
Contacts | |||
Rated operational voltage | Ue | V AC | 600 |
Rated uninterrupted current max. | |||
Main conducting paths | |||
General use | A | 16 | |
Auxiliary contacts | |||
General Use | IU | A | 10 |
Pilot Duty | A 600 P 300 | ||
Switching capacity | |||
Maximum motor rating | |||
Single-phase | |||
120 V AC | HP | 0.5 | |
200 V AC | HP | 1 | |
240 V AC | HP | 1.5 | |
Three-phase | |||
200 V AC | HP | 3 | |
240 V AC | HP | 3 | |
480 V AC | HP | 7.5 | |
600 V AC | HP | 7.5 | |
Short Circuit Current Rating | SCCR | ||
Basic Rating | kA | 5 | |
max. Fuse | A | 50 | |
High fault rating | kA | 10 | |
max. Fuse | A | 20, Class J | |
Terminal capacity | |||
Solid or flexible conductor with ferrule | AWG | 18 – 14 | |
Terminal screw | M3.5 | ||
Tightening torque | lb-in | 8.8 | |
Design verification as per IEC/EN 61439 | |||
Technical data for design verification | |||
Rated operational current for specified heat dissipation | In | A | 20 |
Heat dissipation per pole, current-dependent | Pvid | W | 0.6 |
Equipment heat dissipation, current-dependent | Pvid | W | 0 |
Static heat dissipation, non-current-dependent | Pvs | W | 0 |
Heat dissipation capacity | Pdiss | W | 0 |
Operating ambient temperature min. | °C | -25 | |
Operating ambient temperature max. | °C | 50 | |
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard’s requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard’s requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard’s requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard’s requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | UV resistance only in connection with protective shield. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard’s requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.4 Clearances and creepage distances | Meets the product standard’s requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder’s responsibility. | ||
10.8 Connections for external conductors | Is the panel builder’s responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder’s responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder’s responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder’s responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. | ||
10.12 Electromagnetic compatibility | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. | ||
Technical data ETIM 7.0 | |||
Low-voltage industrial components (EG000017) / Control switch (EC002611) | |||
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Control switch (ecl@ss10.0.1-27-37-14-14 [ACN998011]) | |||
Type of switch | Level switch | ||
Number of poles | 1 | ||
Max. rated operation voltage Ue AC | V | 690 | |
Rated permanent current Iu | A | 20 | |
Number of switch positions | 3 | ||
With 0 (off) position | Yes | ||
With retraction in 0-position | No | ||
Device construction | Built-in device | ||
Width in number of modular spacings | 0 | ||
Suitable for ground mounting | No | ||
Suitable for front mounting 4-hole | Yes |