EATON 101448 Yıldız-Üçgen Zaman Rölesi
Marka: Eaton
Orijinal fiyat: 4.715,82₺.1.650,54₺Şu andaki fiyat: 1.650,54₺.
10.000₺ ve üzeri alışverişlerinize özel teklif.
EATON 101448 DILM32-XTEY20(RAC240) (DILM7-38 için) Kontaktör Aksesuarı: Elek. Zaman Rölesi Yıldız-Üçgen
Datasheet – DILM32-XTEY20(RAC240) | |||
Part no. | DILM32-XTEY20(RAC240) | ||
Article no. | 101448 | ||
Catalog No. | 101448 | ||
2110PIC-206 | |||
Delivery program | |||
Product range | Accessories | ||
Accessories | Timer modules | ||
Description | For star-delta applications Cannot be combined with top mounting auxiliary contacts Incl. suppressor circuits | ||
US | 200 – 240 V AC 50/60 Hz | ||
Time range | Changeover time 1 – 30 s Changeover delay 50 ms | ||
For use with | DILM7 – DILM38 DILMP20 DILMP32-DILMP45 DILA DILMF7 DILMF11 DILMF14 DILMF25 DILMF32 | ||
Contact sequence | 2527SWI-3 | ||
Technical data | |||
General | |||
Standards | DIN EN 61812, IEC/EN 60947, VDE 0660, UL, CSA | ||
Lifespan, mechanical | |||
AC operated | Operations | x 106 | 3 |
DC operated | Operations | x 106 | 3 |
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 | ||
Ambient temperature | |||
Open | °C | -25 – +60 | |
Enclosed | °C | – 25 – 40 | |
Storage | °C | – 40 – 80 | |
Mounting position | As required, except suspended | ||
Mechanical shock resistance (IEC/EN 60068-2-27) | |||
Half-sinusoidal shock, 10 ms | |||
N/O contact | g | 6 | |
N/C contact | g | 6 | |
Degree of Protection | IP20 | ||
Protection against direct contact when actuated from front (EN 50274) | Finger and back-of-hand proof | ||
Weight | kg | 0.08 | |
Terminal capacities | mm2 | ||
Solid | mm2 | 1 x (0.75 – 2.5) 2 x (0.75 – 1.5) | |
Flexible with ferrule | mm2 | 1 x (0.75 – 1.5) 2 x (0.75 – 1.5) | |
Solid or stranded | AWG | 18 – 14 | |
Terminal screw | M3.5 | ||
Pozidriv screwdriver | Size | 2 | |
Standard screwdriver | mm | 0.8 x 5.5 1 x 6 | |
Max. tightening torque | Nm | 1.2 | |
Contacts | |||
Rated impulse withstand voltage | Uimp | V AC | 4000 |
Overvoltage category/pollution degree | III/3 | ||
Rated insulation voltage | Ui | V AC | 250 |
Rated operational voltage | Ue | V | 250 |
Rated operational current | Ie | A | |
AC-15 | |||
220 V 230 V 240 V | Ie | A | 3 |
DC-13 | |||
DC-13 L/R – 15 ms | |||
Contacts in series: | A | ||
1 | 24 V | A | 1 |
1 | 60 V | A | 0.2 |
1 | 110 V | A | 0.2 |
1 | 220 V | A | 0.1 |
DC L/R ≦ 50 ms | |||
Contacts in series: | A | ||
1 | 24 V | A | 1 |
1 | 60 V | A | 0.2 |
1 | 110 V | A | 0.2 |
1 | 220 V | A | 0.1 |
DC-13 L/R – 300 ms | |||
Contacts in series: | A | ||
1 | 24 V | A | 1 |
1 | 60 V | A | 0.2 |
1 | 110 V | A | 0.2 |
1 | 220 V | A | 0.1 |
Safe isolation to EN 61140 | |||
between coil and auxiliary contacts | V AC | 250 | |
between the auxiliary contacts | V AC | 250 | |
Conventional thermal current | Ith | A | 4 |
Short-circuit rating without welding | |||
max. fuse | A gG/gL | 4 | |
Magnet systems | |||
Voltage tolerance | |||
Pick-up voltage | x Us | ||
AC operated | V AC | ||
Pick-up | x Uc | 0.85 – 1.1 | |
DC operated | Pick-up | x Uc | |
Pick-up | x Uc | 0.7 – 1.2 | |
Power consumption | |||
60 °C | Sealing | VA | 2 |
AC operated | Sealing | W | 1.8 |
duty factor | % DF | 100 | |
Maximum operating frequency | Ops./h | ||
Max. operating frequency | Ops/h | 3600 | |
Can be combined with auxiliary contact | Ops./h | 360 | |
Conventional thermal current Ith = Ie AC-1 | |||
On-delayed | ms | < 50 | |
Off-delayed | ms | < 200 | |
AC operated 50 Hz | Deviation | % | < 5 |
Recovery time (after 100% time delay) | ms | 70 | |
contact changeover time | |||
DILM32-XTEE11/DILM32-XTED11 | tu | ms | 10 |
DILM32-XTEY20 | tu | ms | 50 |
Notes | |||
Notes For rated operational current: Making and breaking conditions to DC-13, L/R constant as stated Max. fuses for short-circuit protection: Transparent overlay “Fuses” for time/current characteristics (please enquire) For pick-up voltage, DC operated:Pure DC, AC bridge rectifier or smoothed double-wave rectification. | |||
Rating data for approved types | |||
Auxiliary contacts | |||
Pilot Duty | |||
AC operated | B300 | ||
DC operated | R300 | ||
General Use | |||
AC | V | 240 | |
AC | A | 5 | |
DC | V | 24 | |
DC | A | 5 | |
Short Circuit Current Rating | SCCR | ||
Basic Rating | |||
SCCR | kA | 5 | |
max. Fuse | A | 125 | |
max. CB | A | 125 | |
480 V High Fault | |||
SCCR (fuse) | kA | 10/100 | |
max. Fuse | A | 125/70 Class J | |
SCCR (CB) | kA | 10/65 | |
max. CB | A | 50/32 | |
600 V High Fault | |||
SCCR (fuse) | kA | 10/100 | |
max. Fuse | A | 125/125 Class J | |
SCCR (CB) | kA | 10/22 | |
max. CB | A | 50/32 | |
Design verification as per IEC/EN 61439 | |||
Technical data for design verification | |||
Rated operational current for specified heat dissipation | In | A | 0 |
Heat dissipation per pole, current-dependent | Pvid | W | 0 |
Equipment heat dissipation, current-dependent | Pvid | W | 0 |
Static heat dissipation, non-current-dependent | Pvs | W | 1.8 |
Heat dissipation capacity | Pdiss | W | 0 |
Operating ambient temperature min. | °C | -25 | |
Operating ambient temperature max. | °C | 60 | |
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard’s requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard’s requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard’s requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard’s requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard’s requirements. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard’s requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.4 Clearances and creepage distances | Meets the product standard’s requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder’s responsibility. | ||
10.8 Connections for external conductors | Is the panel builder’s responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder’s responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder’s responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder’s responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. | ||
10.12 Electromagnetic compatibility | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. | ||
Technical data ETIM 7.0 | |||
Relays (EG000019) / Timer block (EC002060) | |||
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Timer block attachment (ecl@ss10.0.1-27-37-13-08 [ACN996011]) | |||
Switching function | Other | ||
Setting time | s | 1 – 30 | |
Number of contacts as normally open contact | 2 | ||
Number of contacts as normally closed contact | 0 | ||
Number of contacts as change-over contact | 0 | ||
Operating principle | Electronic | ||
Approvals | |||
Product Standards | IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking | ||
UL File No. | E29184 | ||
UL Category Control No. | NKCR | ||
CSA File No. | 012528 | ||
CSA Class No. | 3211-03 | ||
North America Certification | UL listed, CSA certified | ||
Dimensions | |||
2527DIM-1 | |||
Additional product information (links) | |||
Motor starters and “Special Purpose Ratings” for the North American market | |||
Switchgear of Power Factor Correction Systems | |||
X-Start – Modern Switching Installations Efficiently Fitted and Wired Securely | |||
Mirror Contacts for Highly-Reliable Information Relating to Safety-Related Control Functions | |||
Effect of the Cabel Capacitance of Long Control Cables on the Actuation of Contactors | |||
Switchgear for Luminaires | |||
Standard Compliant and Functionally Safe Engineering Design with Mechanical Auxiliary Contacts | |||
The Interaction of Contactors with PLCs | |||
Busbar Component Adapters for modern Industri |
Değerlendirme yazabilmek için soturum açmalısınız
Değerlendirmeler
Henüz değerlendirme yapılmadı.