EATON 277949 3NA-1NK Kontaktör Yardımcı Kontağı
Marka: Eaton
Orijinal fiyat: 510,35₺.178,62₺Şu andaki fiyat: 178,62₺.
10.000₺ ve üzeri alışverişlerinize özel teklif.
EATON Kontaktör Aksesuarı: Yardımcı Kontak 3NA+1NK (DILM40-170 için) – 277949
Datasheet – DILM150-XHI31 | |||
Part no. | DILM150-XHI31 | ||
Article no. | 277949 | ||
Catalog No. | 277949 | ||
DILM150-XHI31_L | |||
DILM150-XHI31_C | |||
DILM150-XHI31_R | |||
Delivery program | |||
Accessories | Auxiliary contact modules | ||
Description | with interlocked opposing contacts | ||
Function | for standard applications | ||
Number of poles | 4 pole | ||
Connection technique | Screw terminals | ||
Rated operational current | |||
Conventional free air thermal current, 1 pole | |||
Open | |||
at 60 °C | Ith | A | 16 |
AC-15 | |||
220 V 230 V 240 V | Ie | A | 6 |
380 V 400 V 415 V | Ie | A | 4 |
Contacts | |||
N/O = Normally open | 3 N/O | ||
N/C = Normally closed | 1 NC | ||
Mounting type | Front fixing | ||
Contact sequence | 210S050 | ||
For use with | DILM40… DILM50… DILM65… DILM72… DILM80… DILM95… DILM115… DILM150… DILM170… DILMP63… DILMP80… DILMP125… DILMP160… DILMP200… DILMF40… DILMF50… DILMF65… DILMF80… DILMF95… DILMF115… DILMF150… | ||
Type | Front mounting auxiliary contact | ||
Instructions | Interlocked opposing contacts according to IEC/EN 60947-5-1 Appendix L, inside the auxiliary contact module Auxiliary contacts used as mirror contacts according to IEC/EN 60947-4-1 Appendix F (not N/C late open) | ||
Technical data | |||
General | |||
Standards | IEC/EN 60947, VDE 0660, UL, CSA | ||
Component lifespan | |||
at Ue = 230 V, AC-15, 3 A | Operations | x 106 | 1.3 |
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 | ||
Ambient temperature | |||
Open | °C | -25 – +60 | |
Enclosed | °C | – 25 – 40 | |
Ambient temperature, storage | °C | – 40 – 80 | |
Mechanical shock resistance (IEC/EN 60068-2-27) | |||
Half-sinusoidal shock, 10 ms | |||
Basic unit with auxiliary contact module | g | ||
N/O contact | g | 7 | |
N/C contact | g | 5 | |
Degree of Protection | IP20 | ||
Protection against direct contact when actuated from front (EN 50274) | Finger and back-of-hand proof | ||
Weight | kg | 0.055 | |
Terminal capacities | mm2 | ||
Screw terminals | |||
Solid | mm2 | 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) | |
Flexible with ferrule | mm2 | 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) | |
Solid or stranded | AWG | 18 – 14 | |
Pozidriv screwdriver | Size | 2 | |
Standard screwdriver | mm | 0.8 x 5.5 1 x 6 | |
Max. tightening torque | Nm | 1.2 | |
Contacts | |||
Interlocked opposing contacts within an auxiliary contact module (to IEC 60947-5-1 Annex L) | Yes | ||
N/C contact (not late-break contact) suitable as a mirror contact (to IEC/EN 60947-4-1 Annex F) | DILM40 – DILM170 | ||
Rated impulse withstand voltage | Uimp | V AC | 6000 |
Overvoltage category/pollution degree | III/3 | ||
Rated insulation voltage | Ui | V AC | 690 |
Rated operational voltage | Ue | V AC | 500 |
Safe isolation to EN 61140 | |||
between coil and auxiliary contacts | V AC | 440 | |
between the auxiliary contacts | V AC | 440 | |
Rated operational current | A | ||
Conventional free air thermal current, 1 pole | |||
at 60 °C | Ith | A | 16 |
AC-15 | |||
220 V 230 V 240 V | Ie | A | 6 |
380 V 400 V 415 V | Ie | A | 4 |
500 V | Ie | A | 1.5 |
DC current | |||
Switch-on and switch-off conditions based on DC-13, time constant as specified. | |||
DC L/R ≦ 15 ms | |||
Contacts in series: | A | ||
1 | 24 V | A | 10 |
1 | 60 V | A | 6 |
1 | 110 V | A | 3 |
1 | 220 V | A | 1 |
Control circuit reliability | Failure rate | λ | -8, < one failure at 100 million operations (at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA) |
Short-circuit rating without welding | |||
Short-circuit protection maximum fuse | |||
500 V | A gG/gL | 16 | |
Current heat loss at Ith | |||
AC operated | W | 3.7 | |
DC operated | W | 3.7 | |
Current heat loss per auxiliary circuit at Ie (AC-15/230 V) | CO | 0.5 | |
Rating data for approved types | |||
Auxiliary contacts | |||
Pilot Duty | |||
AC operated | A600 | ||
DC operated | P300 | ||
General Use | |||
AC | V | 600 | |
AC | A | 15 | |
DC | V | 250 | |
DC | A | 1 | |
Design verification as per IEC/EN 61439 | |||
Technical data for design verification | |||
Rated operational current for specified heat dissipation | In | A | 4 |
Heat dissipation per pole, current-dependent | Pvid | W | 0.23 |
Equipment heat dissipation, current-dependent | Pvid | W | 0 |
Static heat dissipation, non-current-dependent | Pvs | W | 0 |
Heat dissipation capacity | Pdiss | W | 0 |
Operating ambient temperature min. | °C | -25 | |
Operating ambient temperature max. | °C | 60 | |
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard’s requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard’s requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard’s requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard’s requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard’s requirements. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard’s requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.4 Clearances and creepage distances | Meets the product standard’s requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder’s responsibility. | ||
10.8 Connections for external conductors | Is the panel builder’s responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder’s responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder’s responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder’s responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. | ||
10.12 Electromagnetic compatibility | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. | ||
Technical data ETIM 8.0 | |||
Low-voltage industrial components (EG000017) / Auxiliary contact block (EC000041) | |||
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Auxiliary switch block (ecl@ss10.0.1-27-37-13-02 [AKN342013]) | |||
Number of contacts as change-over contact | 0 | ||
Number of contacts as normally open contact | 3 | ||
Number of contacts as normally closed contact | 1 | ||
Number of fault-signal switches | 0 | ||
Rated operation current Ie at AC-15, 230 V | A | 6 | |
Type of electric connection | Screw connection | ||
Model | Top mounting | ||
Mounting method | Front fastening | ||
Lamp holder | None | ||
Approvals | |||
Product Standards | IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking | ||
UL File No. | E29184 | ||
UL Category Control No. | NKCR | ||
CSA File No. | 012528 | ||
CSA Class No. | 3211-03 | ||
North America Certification | UL listed, CSA certified | ||
Specially designed for North America | No | ||
Additional product information (links) | |||
Motor starters and “Special Purpose Ratings” for the North American market | |||
Switchgear of Power Factor Correction Systems | |||
X-Start – Modern Switching Installations Efficiently Fitted and Wired Securely | |||
Mirror Contacts for Highly-Reliable Information Relating to Safety-Related Control Functions | |||
Effect of the Cabel Capacitance of Long Control Cables on the Actuation of Contactors | |||
Switchgear for Luminaires | |||
Standard Compliant and Functionally Safe Engineering Design with Mechanical Auxiliary Contacts | |||
The Interaction of Contactors with PLCs | |||
Busbar Component Adapters for modern Industrial control panels |
EATON 277949 3NA-1NK Kontaktör Yardımcı Kontağı için 1 değerlendirme
Değerlendirme yazabilmek için soturum açmalısınız
CÜNEYT KANCA –
Eatonun aradığım kontak ürünüydü burada bulup hemen aldım . Özenli kargoydu.TEŞEKKÜRLER