EATON 259591 NZM2/3 – NZM2/3-XUHIV208-240AC Kompakt Şalter Aksesuarı: Erken Kapama Kontaklı Düşük Gerilim Bobini
Datasheet – NZM2/3-XUHIV208-240AC | |||
Part no. | NZM2/3-XUHIV208-240AC | ||
Article no. | 259591 | ||
Catalog No. | 259591 | ||
1230PIC-1134 | |||
Delivery program | |||
Product range | Accessories | ||
Accessories | Undervoltage release | ||
Accessories | Undervoltage release with early-make auxiliary contact | ||
Standard/Approval | UL/CSA, IEC | ||
Construction size | NZM2/3 | ||
Description | Undervoltage release with 2 early-make auxiliary contacts, e.g., for early-make connection of undervoltage release in main switch applications, as well as for interlock and load shedding circuits. For use with emergency-stop devices in connection with an emergency-stop button. When the under-voltage trip is switched off, accidental contact with the circuit breaker’s primary contacts is prevented when switched on. Early make of auxiliary contacts on switching on and off (manual operation): approx. 20 ms Undervoltage releases cannot be installed simultaneously with NZM…-XHIV… early-make auxiliary contact or NZM…-XA… shunt release. Cannot be used in conjunction with NZM…-XR… remote operator. | ||
Connection type | With bolt connection | ||
Auxiliary contacts | with 2 early-make auxiliary contacts | ||
Rated control voltage | Us | V | 208 – 240 V 50/60 Hz |
For use with | NZM2(-4), N(S)2(-4) NZM3(-4), N(S)3(-4) | ||
Technical data | |||
Undervoltage release | |||
Rated control voltage | Us | V | |
AC | Us | V AC | 208-240 |
Rated control voltage | Us | V | 208 – 240 V 50/60 Hz |
Operating range | |||
Drop-out voltage | x Us | 0.35 – 0.7 | |
Pick-up voltage | x Uc | 0.85 – 1.1 | |
Power consumption | |||
AC | |||
Pick-up AC | VA | 1.5 | |
Sealing AC | VA | 1.5 | |
DC | x Us | ||
Pick-up DC | W | 0.8 | |
Sealing DC | W | 0.8 | |
Maximum opening delay (response time until opening of the main contacts) | ms | 19 | |
Minimum command time | ms | 10 – 15 | |
Terminal capacities | |||
Solid or flexible conductor, with ferrule | mm2 | 1 x (0,75 – 2,5) 2 x (0,75 – 2,5) | |
AWG | 1 x (18 … 14) 2 x (18 … 14) | ||
Design verification as per IEC/EN 61439 | |||
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard’s requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard’s requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard’s requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard’s requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard’s requirements. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard’s requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.4 Clearances and creepage distances | Meets the product standard’s requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder’s responsibility. | ||
10.8 Connections for external conductors | Is the panel builder’s responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder’s responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder’s responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder’s responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. | ||
10.12 Electromagnetic compatibility | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. | ||
Technical data ETIM 7.0 | |||
Low-voltage industrial components (EG000017) / Under voltage coil (EC001022) | |||
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Undervoltage trip (ecl@ss10.0.1-27-37-04-17 [AKF015013]) | |||
Rated control supply voltage Us at AC 50HZ | V | 208 – 240 | |
Rated control supply voltage Us at AC 60HZ | V | 208 – 240 | |
Rated control supply voltage Us at DC | V | 0 – 0 | |
Voltage type for actuating | AC | ||
Type of electric connection | Screw connection | ||
Number of contacts as normally open contact | 2 | ||
Number of contacts as normally closed contact | 0 | ||
Number of contacts as change-over contact | 0 | ||
Delayed | No | ||
Suitable for power circuit breaker | Yes | ||
Suitable for off-load switch | Yes | ||
Suitable for motor safety switch | No | ||
Suitable for overload relay | No | ||
Approvals | |||
Product Standards | UL489; CSA-C22.2 No. 5-09; IEC60947, CE marking | ||
UL File No. | E140305 | ||
UL Category Control No. | DIHS | ||
CSA File No. | 022086 | ||
CSA Class No. | 1437-01 | ||
North America Certification | UL listed, CSA certified |